Necta Dual Zanussi

Notice: Due To Increasing Amounts of Spam:
Links to Outside Websites Are No Longer Allowed
Posts are Now Limited to 2 per day.
Sorry For any Inconvenience.

3 posts / 0 new
Last post
isladeiona
Offline
Last seen: 8 years 10 months ago
Joined: 02/03/2016 - 15:14
Necta Dual Zanussi

Hello I have a Necta Dual vending machine which now keeps blowing the top 10A fuse. This happens after a few mins of powering up when fan kicks in. I thought it was the compressor but my partner has disconnected the compressor and plugged it straight into a wall socket 240v. It seems to run ok, done same thing with fan and that runs ok too.

Could it be something to do with the start up voltage in the machine? Please can someone explain.

Many Thx

AZVendor
Offline
Last seen: 7 years 7 months ago
Joined: 02/07/2014 - 18:59
If it also does this with the compressor unplugged and only

when the fan starts then you probably have a bad fan motor. The compressor may be able to plug directly into the wall and if it runs fine that way then it's okay.

isladeiona
Offline
Last seen: 8 years 10 months ago
Joined: 02/03/2016 - 15:14
Thanks for your help.

Thanks for your help. Unplugged the compressor and machine works ok.Cheers